36 research outputs found

    Detection superiority of 7 T MRI protocol in patients with epilepsy and suspected focal cortical dysplasia

    Get PDF
    In 11 adult patients with suspicion of Focal cortical dysplasia (FCD) on 1.5 T (n = 1) or 3 T (n = 10) magnetic resonance imaging (MRI), 7 T MRI was performed. Visibility, extent, morphological features and delineation were independently rated and subsequently discussed by three observers. Additionally, head-to-head comparisons with corresponding 3 T images were made in the eight patients with a previous 3 T MRI and sustained suspicion of FCD. Comparison with histopathology was done in the five patients that underwent surgery. All lesions, seen at 1.5 and 3 T, were also recognized on 7 T. At 7 T FLAIR highlighted the FCD-like lesions best, whereas T2 and T2* were deemed better suited to review structure and extent of the lesion. Image quality with the used 7 T MRI setup was higher than the quality with the used 3 T MRI setup. In 2 out of 11 patients diagnosis changed, in one after re-evaluation of the images, and in the other based on histopathology. With the used 7 T MRI setup, FCD-like lesions can be detected with more confidence and detail as compared to lower field strength. However, concordance between radiologic diagnosis and final diagnosis seems to be lower than expected

    Ultra-long-TE arterial spin labeling reveals rapid and brain-wide blood-to-CSF water transport in humans

    Get PDF
    The study of brain clearance mechanisms is an active area of research. While we know that the cerebrospinal fluid (CSF) plays a central role in one of the main existing clearance pathways, the exact processes for the secretion of CSF and the removal of waste products from tissue are under debate. CSF is thought to be created by the exchange of water and ions from the blood, which is believed to mainly occur in the choroid plexus. This exchange has not been thoroughly studied in vivo. We propose a modified arterial spin labeling (ASL) MRI sequence and image analysis to track blood water as it is transported to the CSF, and to characterize its exchange from blood to CSF. We acquired six pseudo-continuous ASL sequences with varying labeling duration (LD) and post-labeling delay (PLD) and a segmented 3D-GRASE readout with a long echo train (8 echo times (TE)) which allowed separation of the very long-T2 CSF signal. ASL signal was observed at long TEs (793 ms and higher), indicating presence of labeled water transported from blood to CSF. This signal appeared both in the CSF proximal to the choroid plexus and in the subarachnoid space surrounding the cortex. ASL signal was separated into its blood, gray matter and CSF components by fitting a triexponential function with T2s taken from literature. A two-compartment dynamic model was introduced to describe the exchange of water through time and TE. From this, a water exchange time from the blood to the CSF (Tbl->CSF) was mapped, with an order of magnitude of approximately 60 s

    Quantifying blood-brain barrier leakage in small vessel disease: Review and consensus recommendations

    Get PDF
    Cerebral small vessel disease (cSVD) comprises pathological processes of the small vessels in the brain that may manifest clinically as stroke, cognitive impairment, dementia, or gait disturbance. It is generally accepted that endothelial dysfunction, including blood-brain barrier (BBB) failure, is pivotal in the pathophysiology. Recent years have seen increasing use of imaging, primarily dynamic contrast-enhanced magnetic resonance imaging, to assess BBB leakage, but there is considerable variability in the approaches and findings reported in the literature. Although dynamic contrast-enhanced magnetic resonance imaging is well established, challenges emerge in cSVD because of the subtle nature of BBB impairment. The purpose of this work, authored by members of the HARNESS Initiative, is to provide an in-depth review and position statement on magnetic resonance imaging measurement of subtle BBB leakage in clinical research studies, with aspects requiring further research identified. We further aim to provide information and consensus recommendations for new investigators wishing to study BBB failure in cSVD and dementia. (C) 2019 The Authors. Published by Elsevier Inc. on behalf of the Alzheimer's Association. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).Neuro Imaging Researc

    Design of the ExCersion-VCI study: The effect of aerobic exercise on cerebral perfusion in patients with vascular cognitive impairment

    Get PDF
    There is evidence for a beneficial effect of aerobic exercise on cognition, but underlying mechanisms are unclear. In this study, we test the hypothesis that aerobic exercise increases cerebral blood flow (CBF) in patients with vascular cognitive impairment (VCI). This study is a multicenter single-blind randomized controlled trial among 80 patients with VCI. Most important inclusion criteria are a diagnosis of VCI with Mini-Mental State Examination ≥22 and Clinical Dementia Rating ≤0.5. Participants are randomized into an aerobic exercise group or a control group. The aerobic exercise program aims to improve cardiorespiratory fitness and takes 14 weeks, with a frequency of three times a week. Participants are provided with a bicycle ergometer at home. The control group receives two information meetings. Primary outcome measure is change in CBF. We expect this study to provide insight into the potential mechanism by which aerobic exercise improves hemodynamic status

    ExploreASL: An image processing pipeline for multi-center ASL perfusion MRI studies

    Get PDF
    Arterial spin labeling (ASL) has undergone significant development since its inception, with a focus on improving standardization and reproducibility of its acquisition and quantification. In a community-wide effort towards robust and reproducible clinical ASL image processing, we developed the software package ExploreASL, allowing standardized analyses across centers and scanners. The procedures used in ExploreASL capitalize on published image processing advancements and address the challenges of multi-center datasets with scanner-specific processing and artifact reduction to limit patient exclusion. ExploreASL is self-contained, written in MATLAB and based on Statistical Parameter Mapping (SPM) and runs on multiple operating systems. To facilitate collaboration and data-exchange, the toolbox follows several standards and recommendations for data structure, provenance, and best analysis practice. ExploreASL was iteratively refined and tested in the analysis of >10,000 ASL scans using different pulse-sequences in a variety of clinical populations, resulting in four processing modules: Import, Structural, ASL, and Population that perform tasks, respectively, for data curation, structural and ASL image processing and quality control, and finally preparing the results for statistical analyses on both single-subject and group level. We illustrate ExploreASL processing results from three cohorts: perinatally HIV-infected children, healthy adults, and elderly at risk for neurodegenerative disease. We show the reproducibility for each cohort when processed at different centers with different operating systems and MATLAB versions, and its effects on the quantification of gray matter cerebral blood flow. ExploreASL facilitates the standardization of image processing and quality control, allowing the pooling of cohorts which may increase statistical power and discover between-group perfusion differences. Ultimately, this workflow may advance ASL for wider adoption in clinical studies, trials, and practice

    Visualizing the Human Subcortex Using Ultra-high Field Magnetic Resonance Imaging

    Get PDF

    A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice

    Get PDF

    A framework for motion correction of background suppressed arterial spin labeling perfusion images acquired with simultaneous multi-slice EPI

    No full text
    Purpose: When using simultaneous multi-slice (SMS) EPI for background suppressed (BGS) arterial spin labeling (ASL), correction of through-plane motion could introduce artefacts, because the slices with most effective BGS are adjacent to slices with the least BGS. In this study, a new framework is presented to correct for such artefacts.Methods: The proposed framework consists of 3 steps: (1) homogenization of the static tissue signal over the different slices to eliminate most inter-slice differences because of different levels of BGS, (2) application of motion correction, and (3) extraction of a perfusion-weighted signal using a general linear model. The proposed framework was evaluated by simulations and a functional ASL study with intentional head motion.Results: Simulation studies demonstrated that the strong signal differences between slices with the most and least effective BGS caused sub-optimal estimation of motion parameters when through-plane motion was present. Although use of the M-0 image as the reference for registration allowed 82% improvement of motion estimation for through-plane motion, it still led to residual subtraction errors caused by different static tissue signal between control and label because of different BGS levels. By using our proposed framework, those problems were minimized, and the accuracy of CBF estimation was improved. Moreover, the functional ASL study showed improved detection of visual and motor activation when applying the framework as compared to conventional motion correction, as well as when motion correction was completely omitted.Conclusion: When combining BGS-ASL with SMS-EPI, particular attention is needed to avoid artefacts introduced by motion correction. With the proposed framework, these issues are minimized.Neuro Imaging Researc
    corecore